01628 588755
support@colourgen.com
Copyright © All rights reserved. Colourgen Limited January 2012 Privacy policy
Stylus Pro GS6000 User Guides
Stylus Pro GS6000 Error Codes
Maintenance Request Errors
MAINTENANCE REQ - 0001 - CR scan pass counter reached the specified value.
MAINTENANCE REQ - 0011 - The RTC backup battery becomes exhausted.
MAINTENANCE REQ - 0111 - The date has not been set.
MAINTENANCE REQ - 0100 - The following two errors are occurring, 0001 & 0011
MAINTENANCE REQ - 1000 - The following two errors are occurring, 0001 & 0011
MAINTENANCE REQ - 1010 - The following two errors are occurring, 0011 & 0111

Service Call Errors
SERVICE CALL - 1101 - Life end of the CR MOTOR
SERVICE CALL - 1125 - Carriage home position detection
SERVICE CALL - 1133 - CR MOTOR in position time-out error
SERVICE CALL - 1135 - CR ENC ASSY check error
SERVICE CALL - 1136 - CR MOTOR step-out error
SERVICE CALL - 1137 - CR servo parameter error
SERVICE CALL - 1223 - PF ENCODER ASSY check error
SERVICE CALL - 1225 - PF MOTOR in position time-out error
SERVICE CALL - 1227 - PF MOTOR step-out error
SERVICE CALL - 1228 - PF servo parameter error
SERVICE CALL - 131B - Head driver (transmission gate) overheat error
SERVICE CALL - 1700 - Print position error
SERVICE CALL - 1900 - HEATER CONT BOARD serial connection failure
SERVICE CALL - 1902 - Over Temp PRE HEATERS(64) on the HEATER RELAY
SERVICE CALL - 1903 - Over Temp PLATEN HEATER(64) on the HEATER RELAY
SERVICE CALL - 1904 - Over Temp AFTER HEATER(64) on the HEATER RELAY
SERVICE CALL - 1905 - Over Temp PRE HEATERS(64) on the HEATER RELAY
SERVICE CALL - 1906 - Over Temp PLATEN HEATER(64) on the HEATER RELAY
SERVICE CALL - 1907 - Over Temp AFTER HEATER(64) on the HEATER RELAY
SERVICE CALL - 1908 - An abnormal voltage of the heater on the HEATER CONT
SERVICE CALL - 1909 - Comms Failure HEATER CONT BOARD and SUB-Board
SERVICE CALL - 1910 - Under Temp PRE HEATERS(64) on the HEATER RELAY
SERVICE CALL - 1911 - Under Temp PLATEN HEATER on the HEATER RELAY
SERVICE CALL - 1912 - Under Temp AFTER HEATER on the HEATER RELAY
SERVICE CALL - 1920 - HEATER CONT BOARD -SUB TANK SENSOR 1 failure
SERVICE CALL - 1921 - HEATER CONT BOARD -SUB TANK SENSOR 2 failure
SERVICE CALL - 1922 - HEATER CONT BOARD -SUB TANK SENSOR 3 failure
SERVICE CALL - 1923 - HEATER CONT BOARD -SUB TANK SENSOR 4 failure
SERVICE CALL - 1924 - HEATER CONT BOARD -SUB TANK SENSOR 5 failure
SERVICE CALL - 1925 - HEATER CONT BOARD -SUB TANK SENSOR 6 failure
SERVICE CALL - 1926 - HEATER CONT BOARD -SUB TANK SENSOR 7 failure
SERVICE CALL - 1927 - HEATER CONT BOARD -SUB TANK SENSOR 8 failure
SERVICE CALL - 1A23 - RTC analysis error
SERVICE CALL - 1A26 - RTC communication error
SERVICE CALL - 1A37 - Head thermistor error
SERVICE CALL - 1A38 - Transistor thermistor error
SERVICE CALL - 1A39 - Head error
SERVICE CALL - 1A40 - MAIN BOARD ASSY IC2 error
SERVICE CALL - 1A41 - Head rank ID input error
SERVICE CALL - 2000 - NVRAM error
SERVICE CALL - 2002 - SDRAM error
SERVICE CALL - 2003 - Boot program sum error
SERVICE CALL - 200A - Program loading error
SERVICE CALL - 200B - Internal insufficient memory error
SERVICE CALL - 200C - Servo interrupt watchdog time-out error
SERVICE CALL - 200D - System interrupt watchdog timeout error
SERVICE CALL - 200E - Unknown NMI
SERVICE CALL - 3000 - AC power shut-off
SERVICE CALL - FXXX - CPU-related error