01628 588755
support@colourgen.com
Copyright © All rights reserved. Colourgen Limited January 2012 Privacy policy
Stylus Pro 7400 User Guides
Stylus Pro 7400 Error Codes
Maintenance Requests Errors
MAINTENANCE REQ - 0002 - CR movement cycles reached the specified value.
MAINTENANCE REQ - 0008 - The RTC backup battery run down or is not installed.
MAINTENANCE REQ - 0040 - The pump counter reached the specified upper limit.
MAINTENANCE REQ - 0080 - The date and time has not been set.
MAINTENANCE REQ - 0100 - A momentary drop in voltage of the RTC backup battery
MAINTENANCE REQ - 0400 - Pressure Pump counter reached the specified limit.

Service Request Errors
SERVICE REQ - 00000101 - The CR Motor reached its end of life.
SERVICE REQ - 00010000 - PF Encoder check error
SERVICE REQ - 00010001 - The PF Motor is out of step.
SERVICE REQ - 00010002 - Overcurrent occurred on the PF Motor.
SERVICE REQ - 00010003 - The PF Motor out of position time-out error
SERVICE REQ - 00010004 - CR Encoder check error
SERVICE REQ - 00010005 - CR Motor is out of step.
SERVICE REQ - 00010007 - The CR Motor out of position time-out error
SERVICE REQ - 00010008 - Servo interrupt watchdog time-out error
SERVICE REQ - 00010009 - System interrupt watchdog time-out error
SERVICE REQ - 0001000A - Carriage home position detection error
SERVICE REQ - 0001000C - PG home position detection error
SERVICE REQ - 00010014 - Failure of pressurizing
SERVICE REQ - 0001001B - Head driver (TG) temperature error
SERVICE REQ - 0001001D - CR servo parameter error
SERVICE REQ - 0001001E - PF servo parameter error
SERVICE REQ - 00010020 - CSIC reading/writing error
SERVICE REQ - 00010023 - RTC analyzing error
SERVICE REQ - 00010026 - RTC communication error
SERVICE REQ - 00010027 - Pressure pump micro air-leak error
SERVICE REQ - 00010028 - Head error
SERVICE REQ - 0001002A - CR ASIC ECU error
SERVICE REQ - 0001002D - The Cleaning Unit reached its end of life.
SERVICE REQ - 00010035 - Pump phase detection error
SERVICE REQ - 00010036 - Type-B board installation error
SERVICE REQ - 00010037 - Head thermistor error
SERVICE REQ - 00010038 - Transistor thermistor error
SERVICE REQ - 0001003E - Pressure Sensor failure
SERVICE REQ - 0001003F - The Pressure Motor reached its end of life.
SERVICE REQ - 00010040 - Printing position error
SERVICE REQ - 00020000 - NVRAM error
SERVICE REQ - 00020002 - SDRAM error
SERVICE REQ - 00020003 - Boot program sum error
SERVICE REQ - 0002000A - Program load error
SERVICE REQ - 0002000B - The internal memory is insufficient.
SERVICE REQ - 0Dxxxxxx - An error code for debugging
SERVICE REQ - 0Exxxxxx - A time-lag of the RTC timer
SERVICE REQ - 100000E0 - CPU address error (load)
SERVICE REQ - 10000100 - CPU address error (store)
SERVICE REQ - 10000180 - CPU reserved command code exception error
SERVICE REQ - 100001A0 - CPU slot undefined command exception error
SERVICE REQ - 100001C0 - The AC power is shut off.
SERVICE REQ - 100005C0 - CPU DMA address error
SERVICE REQ - 10000xxx - CPU error