Stylus Pro 4400 User Guides
Stylus Pro 4400 Error Codes
Maintenance Requests Errors
MAINTENANCE REQ - 0002 - CR movement cycles has reached predetermined value
MAINTENANCE REQ - 0008 - RTC backup battery shut off
MAINTENANCE REQ - 0040 - Pump counter has reached predetermined amount.
MAINTENANCE REQ - 0080 - Date is not set
MAINTENANCE REQ - 0088 - RTC backup battery is not installed.
MAINTENANCE REQ - 0100 - RTC backup battery pressure is temporally low.
MAINTENANCE REQ - 0200 - ASF paper feeding has reached predetermined value.

Service Request Errors
SERVICE REQ - 00000101 - CR Motor life
SERVICE REQ - 00010000 - PF Motor Encoder check error
SERVICE REQ - 00010001 - PF Motor out of step
SERVICE REQ - 00010002 - PF Motor over current
SERVICE REQ - 00010003 - PF Motor in-position time-out
SERVICE REQ - 00010004 - CR Motor Encoder check error
SERVICE REQ - 00010005 - CR Motor out of step
SERVICE REQ - 00010006 - CR Motor over current
SERVICE REQ - 00010007 - CR Motor in-position time-out
SERVICE REQ - 00010008 - Servo interrupt watchdog time-out
SERVICE REQ - 00010009 - System interrupt watchdog time-out
SERVICE REQ - 0001000A - CR axis detection error
SERVICE REQ - 0001000C - PG axis detection error
SERVICE REQ - 0001000F - CR Motor PWM output faulty
SERVICE REQ - 00010010 - PF Motor PWM output faulty
SERVICE REQ - 00010012 - CR overload (high sensitivity) error
SERVICE REQ - 00010013 - PR overload (high sensitivity) error
SERVICE REQ - 0001001B - Head driver (TG) temperature error
SERVICE REQ - 0001001D - CR servo parameter error
SERVICE REQ - 0001001E - PF servo parameter error
SERVICE REQ - 00010020 - CSIC reed/right error
SERVICE REQ - 00010022 - Ink type error (setting on printer body side)
SERVICE REQ - 00010023 - RTC analysis error
SERVICE REQ - 00010025 - CSIC ROM communication error
SERVICE REQ - 00010026 - RTC communication error
SERVICE REQ - 00010028 - Head error
SERVICE REQ - 00010029 - Unidentified NMI
SERVICE REQ - 0001002A - CR ASIC ECU error
SERVICE REQ - 0001002B - PF ASIC ECU error
SERVICE REQ - 0001002D - Cleaning Unit work life error
SERVICE REQ - 0001002F - 360 DPI writing time out error
SERVICE REQ - 00010030 - Multi Sensor failure
SERVICE REQ - 00010031 - ASF phase detection error
SERVICE REQ - 00010032 - ASF drive switch error
SERVICE REQ - 00010033 - Eject phase detection error
SERVICE REQ - 00010034 - Eject movement error
SERVICE REQ - 00010035 - Pump phase detection error
SERVICE REQ - 00010036 - Type-B board installation error
SERVICE REQ - 00010037 - Head thermistor error
SERVICE REQ - 00010038 - Transistor thermistor error
SERVICE REQ - 00010039 - PG adjustment value incorrect overwrite error
SERVICE REQ - 0001003A - PG adjustment value outside range error
SERVICE REQ - 0001003B - Cutter installation error 1
SERVICE REQ - 0001003C - Cutter installation error 2
SERVICE REQ - 0001003D - Cutter installation error 3
SERVICE REQ - 00020000 - NVRAM error
SERVICE REQ - 00020002 - SDRAM error
SERVICE REQ - 00020003 - BOOT program SUM error
SERVICE REQ - 00020009 - Flash memory SUM error
SERVICE REQ - 0002000A - Program load error
SERVICE REQ - 0002000B - Internal memory shortage error
SERVICE REQ - 100000E0 - CPU address error (load misalignment)
SERVICE REQ - 10000100 - CPU address error (storage misalignment)
SERVICE REQ - 10000180 - CPU reserve command code exception error
SERVICE REQ - 100001A0 - CPU slot illegal command exception error
SERVICE REQ - 100001C0 - AC disruption
SERVICE REQ - 100005C0 - CPU DMA address error
SERVICE REQ - 10000xxx - CPU error
SERVICE REQ - 0003xxxx - Debug error code
SERVICE REQ - 0Dxxxxxx - Debug error code
SERVICE REQ - 0Exxxxxx - RTC timer off error
Copyright © All rights reserved. Colourgen Limited January 2012 Privacy policy